Loading
Get Hvt Series Terminations 5-35kv Class High Voltage Termination
How it works
-
Open form follow the instructions
-
Easily sign the form with your finger
-
Send filled & signed form or save
How to use or fill out the HVT Series Terminations 5-35kV Class High Voltage Termination online
Filling out the HVT Series Terminations 5-35kV Class High Voltage Termination online can seem like a daunting task. This guide will provide clear, step-by-step instructions to help users complete the form efficiently and accurately.
Follow the steps to fill out the form correctly.
- Click the ‘Get Form’ button to obtain the form and open it in the editor.
- Begin by reviewing the kit contents listed in the document to ensure you have all necessary items before starting the form. Each item plays a vital role in the installation process.
- Read through the ‘General Instructions’ section for essential preparatory steps and safety information. Familiarize yourself with the recommended tools and installation equipment.
- Detail the selection of the product based on your cable's specifications. Refer to Table 1 for conductor sizes and insulation dimensions, tailoring the installation kit selection to match your cable requirements.
- Prepare your cables according to Table 2 specifications. Choose the correct cable type and follow the diagram in Figure 1 for insulation cutback instructions.
- If required, install the ground braid for copper tape shield cables by following the specific steps outlined. If using other cable types, proceed to the next instructions accordingly.
- Clean and abrade the cable insulation as needed. Refer to your installation instructions to ensure proper cleaning methods are applied.
- Apply stress relief material at the semi-con cutback. Ensure that the SRM is tightly wrapped to maintain insulation integrity.
- Once preparation is complete, position the black stress control tube and begin the shrinking process carefully with a flame.
- Conduct the final grounding steps based on your cable type and proceed to apply red sealant on the jacket. Ensure all steps are meticulously followed to avoid water ingress.
- Finally, position the red HV tube and shrink it in place. Make sure the installed components meet the specified requirements.
- If performing outdoor terminations, position and shrink the skirts as per the voltage class requirements listed in the document.
- Once all steps are completed, review your work for any corrections. You may choose to save changes, download, or print the final documentation.
Complete your high voltage terminations form online today to ensure your project progresses smoothly and efficiently.
Redaction can be done manually by blacking out or whiting out sensitive information on a physical document or by editing electronic documents using software tools that allow users to obscure selected information.
Industry-leading security and compliance
US Legal Forms protects your data by complying with industry-specific security standards.
-
In businnes since 199725+ years providing professional legal documents.
-
Accredited businessGuarantees that a business meets BBB accreditation standards in the US and Canada.
-
Secured by BraintreeValidated Level 1 PCI DSS compliant payment gateway that accepts most major credit and debit card brands from across the globe.