HemoCue Hemoglobin Quality Control Log Daily Control Cuvette Reading Serial Number Control Cuvette Assayed Value 0.3 g/dl MONTH DATE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 READING DATE 17 18 19 20.

How it works
  • Open form

    Open form follow the instructions

  • Easily sign form

    Easily sign the form with your finger

  • Share form

    Send filled & signed form or save

How to fill out the Control Log Sheet Hemocue Glucose 201 online

This guide provides users with clear instructions on how to effectively fill out the Control Log Sheet for Hemocue Glucose 201 online. Understanding each component of the form will help ensure accurate record-keeping and improve overall management of glucose testing.

Follow the steps to accurately complete your Control Log Sheet.

  1. Click the ‘Get Form’ button to access the Control Log Sheet and open it in your preferred editor.
  2. Begin by entering the serial number of the control cuvette in the designated field at the top of the form. This number helps identify the specific cuvette used during testing.
  3. Next, input the control cuvette assayed value in the appropriate field, ensuring that the reading does not equal 0.3 g/dl. This is critical for maintaining the quality of your readings.
  4. In the 'MONTH' section, specify the month during which the readings are recorded to keep your documentation organized.
  5. Proceed to fill in the date columns for the first half of the month. For each date from 1 to 16, enter the corresponding reading in the 'READING' column adjacent to the date.
  6. Continue to fill in the remaining dates from 17 to 31 in the designated date columns, making sure to record the readings accurately in the respective 'READING' column.
  7. Once all fields are completed, review your entries for accuracy and consistency before finalizing the form.
  8. After ensuring all information is correct, you can save changes to the document, download it for your records, print it, or share it as required.

Take action now and complete your documents online for efficient management of your glucose testing records.

Get form

Experience a faster way to fill out and sign forms on the web. Access the most extensive library of templates available.

Related content

QC Worksheet for HemoCue Hemoglobin Determination

Health Department Page __of___. Quality Control Log Sheet. Site: Month ______ Year ______...

Learn more
THE OHIO STATE UNIVERSITY MEDICAL CENTER

Dec 5, 2019 — The HemoCue Hb 201 DM is a system used for the determination of the total...

Learn more
Questions & Answers

Get answers to your most pressing questions about US Legal Forms API.

Contact support

What kind of controls should be used with the HemoCue hb 201 system?

The HemoCue® Hb 201+ System is easy to use, requires no controls and provides lab-quality results in less than one minute.

0:30 11:42 HemoCue Glucose 201 Training - YouTube YouTube Start of suggested clip End of suggested clip Form. The micro cuvette is used for collecting the sample. And as a reaction vessel and measuringMoreForm. The micro cuvette is used for collecting the sample. And as a reaction vessel and measuring cuvette. When the reaction is complete the glucose result is displayed as a plasma equivalent.

Clean the Hemo c C ue 201+ case each day of use with a clean cloth which has been dampened with a mild disinfectant lcohol ( non-phenolic) ethanol or isopropyl alcohol) or a mild soap solution . Allow the disinfectant 1-2 minutes contact time. Wipe off the disinfectant with a damp cloth. Use no abrasives at any time.

Wait 15 minutes before replacing the cuvette holder and using the analyzer. Make sure the cuvette holder is dry before inserting.

The filled (test) microcuvette should be analyzed within 10 minutes after being filled. Filled (test) microcuvettes are to be kept in the horizontal position. Place the filled (test)microcuvettes into the cuvette holder and gently slide the holder into measuring position. 16.

All monitors at each patient testing site will have QC run once every 24 hours, analyzing two levels of control material (low and high). Quality control for the DM HemoCue consists of a Red Control Cuvette (QCC), Low Control (QCL), and a High Control (QCH).

Storage and handling of the HemoCue Hb 201 Microcuvettes The microcuvettes are to be stored at a temperature of 15–30 °C (59–86 °F) and in a dry place. Do not refrigerate. Use the microcuvettes prior to the expiration date that is printed on each package.

Once opened, the microcuvettes are stable for three (3) months. Tightly reseal container immediately after use. Write both the date opened and the open vial expiration date on the container. NOTE: Only microcuvettes designated for use in the HemoCue 201+ instrument may be used.

Venous or arterial blood is recommended for use on the HemoCue Hb instrument. Bloods must be collected into an EDTA or tube. Capillary samples can be used but results should be interpreted with caution. If the blood has been stored in a refrigerator it must be allowed to reach room temperature before analysis.

Get This Form Now!

Use professional pre-built templates to fill in and sign documents online faster. Get access to thousands of forms.

If you believe that this page should be taken down, please follow our DMCA take down process here.

Get Control Log Sheet Hemocue Glucose 201