A, 340A, 340M, 345M, 350A, 350M, 351D, 352A, 352M, 355A, 355B, 355C, 355M, 398A, 398B, 399A 58SX, SXA, SXB, SXC, DX, DXA, DXC, VCA, VUA, MCA, MCB, MXA, MXB, MSA, UVB, MVP, MVB, MVC, MTA, MTB 490A, PG9MAA, PG9MAB SITUATION: There are several furnace heat exchanger inspection methodologies that have been used in the field. Improper or inadequate furnace heat exchanger inspection techniques can result in the misdiagnosis of a heat exchanger failure when a failure has not occurred or is not imminent.
Open form follow the instructions
Easily sign the form with your finger
Send filled & signed form or save
How to fill out the Carrier Smb 09 0022 online
Filling out the Carrier Smb 09 0022 form accurately is essential for the proper inspection and documentation of furnace heat exchangers. This guide provides step-by-step instructions to assist users in completing the form effectively.
Follow the steps to accurately complete the Carrier Smb 09 0022 form.
- Click the ‘Get Form’ button to access the Carrier Smb 09 0022 document in the online editor.
- Begin by filling out the required fields indicated with an asterisk (*), such as the customer name, address, and phone number. Ensure that all personal information is accurate.
- Input the furnace model number and serial number, which can usually be found on the unit's identification label.
- Record the CO reading in parts per million (ppm) and the excess air level percentage, noting that both readings are required if the furnace is operational.
- Proceed to the installation checklist and mark all areas that have been examined during the inspection, confirming compliance with the inspection procedure.
- In the maintenance items section, check all items that were cleaned or inspected, including air filters, blower motor/wheel, and heat exchangers.
- After completing the inspection and addressing any maintenance issues, conduct a combustion retest and document any observed CO readings and excess air levels for the second test.
- Review your inputs for accuracy and completeness. Ensure all required fields marked with a double asterisk (**) have been filled out.
- Sign the form in the designated area to certify the inspection results. Be sure to fill in your name and dealer information.
- Submit the completed form by faxing it to Warranty Administration at (860) 998-2941 or emailing it to admin.sams@carrier.utc.com with SMB09-0022 in the subject line.
Complete your Carrier Smb 09 0022 online today for efficient furnace inspection documentation.
Experience a faster way to fill out and sign forms on the web. Access the most extensive library of templates available.
Related content
Sep 25, 2009 — ... 0022, dated December 23, 2008, it has received six reports of debris...
Who may enroll in this Plan: All Federal employees and annuitants who are eligible to...
Apr 30, 2017 — The secondary heat exchanger meets the visual inspection failure criteria...
Get answers to your most pressing questions about US Legal Forms API.
What is the settlement for the carrier furnace lawsuit?
This settlement is not about personal injuries, wrongful death, or emotional distress. Carrier will pay those included in the settlement up to $270 for an eligible secondary heat exchanger failure and offer an enhanced 20-year warranty on secondary heat exchangers in their high efficiency gas furnaces.
How do I know if my secondary heat exchanger is bad?
A malfunctioning heat exchanger will often create an unpleasant and strong odor that smells similar to formaldehyde. Soot Build-up. White soot build-up in or around the burners of your furnace. Corrosion & Cracks.
How do I know if my heat exchanger is bad?
Warning Signs of Cracked Heat Exchangers Visible Damage. You may be able to see cracks in the heat exchanger when you visually inspect the furnace. ... Soot. The presence of soot on the heat exchanger or on the furnace's interiors is a warning sign of incomplete combustion. ... Abnormal Flame. ... Noticeable Odors. ... Water on the Floor.
What does the secondary heat exchanger do?
The secondary heat exchanger accepts combustion heat exhaust from the primary heat exchanger. It provides more heat from the flue gas, forcing water vapor to change its state to liquid, releasing latent heat into the secondary heat exchanger. This process makes the furnace much more efficient.
How do I know if heat exchanger is faulty?
Faulty boiler heat exchanger symptoms Noises coming from boiler. If you have started to notice strange noises coming from your boiler, this may be indicative of a faulty heat exchanger. ... Leakages. Noises from the boiler can be a sign of a build-up of debris in the heat exchanger. ... Dirty radiator water.
How much does it cost to replace a furnace heat exchanger?
Were you recently told that your furnace heat exchanger is cracked and needs to be replaced? If so, here's the thing: replacing a heat exchanger isn't as simple or affordable as it sounds. In fact, replacing a furnace heat exchanger can take up to 8 hours and can cost anywhere from $2,000 to $3,500.
What are the symptoms of a bad secondary heat exchanger?
Immediately call an HVAC professional to assess your furnace if you notice any symptoms of a bad heat exchanger: Orange, yellow, or flickering burner flames. Pungent smells. Rattling, popping, or banging sounds. Carbon monoxide detection. Corroded or damaged components. Poor heating. Cracked heat exchanger.
How often should secondary heat exchangers be replaced?
Replacing a Heat Exchanger vs. Furnaces usually last between 15 and 20 years. If your heat exchanger fails when the furnace is 10 years old or more, it might be best to purchase a new furnace rather than replace the heat exchanger.