                Get Encoder Calibration Procedures For The Ft-50 And Ft-70. Ft-50,ft-70,encoder
How it works
- 
                    Open form follow the instructions
- 
                    Easily sign the form with your finger
- 
                    Send filled & signed form or save
How to fill out the Encoder Calibration Procedures For The FT-50 And FT-70 online
This guide provides clear and comprehensive instructions on how to complete the Encoder Calibration Procedures for the FT-50 and FT-70. Following these steps will help ensure accurate calibration for efficient operation.
Follow the steps to complete the calibration procedure.
- Click ‘Get Form’ button to obtain the calibration form and open it for editing.
- Begin by determining the software version baseline in your inspection unit. Turn on the FT-50 or FT-70 to view the software version displayed during the start-up sequence.
- Select the appropriate calibration procedure based on the software version. There are specific protocols for baseline eight or newer and separately for baseline seven or older units.
- Remove the cover from the FT-50/70 to access the dip switch pack S1. Adjust the settings for S1-5 and S1-6 as specified in the steps relevant to your calibration type.
- Enter 'Calibrate Mode' by pressing Key 5 until the system display appears. If prompted, enter your password.
- Check the rejector status by pressing Key 4 and make sure it is activated. Use the Arrow Key to turn it on if necessary.
- Follow the specific calibration procedures detailed under Standard Calibration, Unknown Sprocket Size Calibration, or Non-Standard Conveyor Calibration, depending on the type of conveyor and sprocket details you have.
- Input all necessary measurements including conveyor speed, container dimensions, and sprocket teeth based on the established measurement standards.
- After completing the input, ensure to run a test container through the system to check the rejector timing and make necessary adjustments based on the performance.
- Once all adjustments are made, save your settings, return to the System Display, and select the Operate Mode to finalize the calibration procedure.
Complete your documents online to ensure efficient calibration and operation.
Calibration is the process of configuring an instrument to provide a result for a sample within an acceptable range. Eliminating or minimizing factors that cause inaccurate measurements is a fundamental aspect of instrumentation design.
Industry-leading security and compliance
US Legal Forms protects your data by complying with industry-specific security standards.
        - 
                    In businnes since 199725+ years providing professional legal documents.
- 
                    Accredited businessGuarantees that a business meets BBB accreditation standards in the US and Canada.
- 
                    Secured by BraintreeValidated Level 1 PCI DSS compliant payment gateway that accepts most major credit and debit card brands from across the globe.