Appleton and OZ/Gedney Conduit Bodies Maximum Wire Fill Comparison Appleton OZ/GedneyForm 35 Spec 5Form 85 AluminumMogul MogulFM7 Form 7FM8 FM9 Trade SizeBody Style1/2 "All3/4 "C LB LL LR.

How it works

  1. Open form

    Open form follow the instructions

  2. Easily sign form

    Easily sign the form with your finger

  3. Share form

    Send filled & signed form or save

How to fill out the Appleton Conduit Body Fill Chart online

The Appleton Conduit Body Fill Chart is an essential tool for determining the maximum wire fill capacity of conduit bodies. This guide provides clear, step-by-step instructions to help users complete the form effectively, ensuring compliance with relevant electrical codes.

Follow the steps to complete the Appleton Conduit Body Fill Chart online.

  1. Press the ‘Get Form’ button to access the Appleton Conduit Body Fill Chart and open it in your preferred online editor.
  2. Begin by identifying the trade size at the top of the chart. This section is crucial as it determines the appropriate wire fill limits based on the size of the conduit.
  3. Next, locate the body style options listed under each trade size. Carefully select the body style that corresponds to your project requirements.
  4. In this section, review the maximum wire counts for each conductor size, which are specified in parentheses. Ensure you do not exceed these values when planning your conductor installation.
  5. Take note of the guidelines provided regarding conductor sizes and their respective fill calculations. This includes ensuring that the total cross-sectional area of your selected conductors does not surpass the area allowed for the maximum size indicated.
  6. Once all sections are filled out correctly, use the options available to save changes, download the completed chart, print it for physical records, or share it with relevant parties.

Complete your Appleton Conduit Body Fill Chart online today for efficient and compliant wiring solutions.

Get form

Experience a faster way to fill out and sign forms on the web. Access the most extensive library of templates available.
Get form

Related content

BASIC MATERIALS AND METHODS SECTION 16100 - BidNet
Apr 15, 2019 — Conduit and fittings must be rigid galvanized steel, heavy wall type...
Learn more
Appleton – O-Z/Gedney – Conduit Bodies...
Appleton – O-Z/Gedney – Conduit Bodies. Conductor Bending RADII. TYPE LB with Gasket...
Learn more

Related links form

NY RP-466-a - Rockland Steuben 2007 AL 40A 2021 CA RHFPD Senior Citizen Measure O Parcel Tax Exemption Claim 2022 PA DEX-41 2022

Questions & Answers

Get answers to your most pressing questions about US Legal Forms API.

Contact support

The 2020 NEC (National Electrical Code) allows the following in a 1 inch schedule 40 RMC (rigid metal conduit): 12 AWG with Type TW, THHW, THW, THW-2 insulation: 19 wires.

If the removable cover is on top or on the back of the conduit body, it is an LB, with the “B” standing for “back.” If the cover is on the left side of the conduit body, then it is an “LL,” the “L” standing for “left.” If the cover is on the right side of the conduit body, then it is an “LR,” with the “R” standing for ...

The NEC specifications are: One wire: maximum fill is 53% of the space inside a conduit. Two wires: maximum fill is 31% Three wires or more: maximum fill is 40% of the conduit's total available space.

Allowable Conduit Fill Capacities Size and Type of Conduit14 AWG Wire10 AWG Wire1/2-inch EMT1253/4-inch EMT22101-inch EMT35161 1/2-inch EMT843811 more rows • 5 Mar 2022

DiameterStandard RTRC Spacing DistanceGRC And PVC-coated Steel Support Spacing Distance1″3 ft.12 ft.1-1/4″5 ft.14 ft.1-1/2″5 ft.14 ft.2″5 ft.16 ft.6 more rows • 18 Oct 2022

The National Electrical Code establishes that if a conduit only contains 1 wire, the max fill percentage is 53%. If it contains 2 wires, the max fill percentage is 31%. And if it contains 3 or more wires, the max fill percentage is 40%.

A conduit trade size of 1 inch has an actual inner diameter of 1.049 inches. 2-inch lengths typically have an inside diameter of 2.067 inches.

ing to NEC Code 300.17, the following are the limits allowed for conductors based on size and number: One wire can fill no more than 53% of a conduit. Two wires can fill no more than 31% of a conduit. Three or more wires can fill no more than 40% of a conduit.

Get This Form Now!

Use professional pre-built templates to fill in and sign documents online faster. Get access to thousands of forms.
Get form
If you believe that this page should be taken down, please follow our DMCA take down processhere.

Industry-leading security and compliance

US Legal Forms protects your data by complying with industry-specific security standards.
  • In businnes since 1997
    25+ years providing professional legal documents.
  • Accredited business
    Guarantees that a business meets BBB accreditation standards in the US and Canada.
  • Secured by Braintree
    Validated Level 1 PCI DSS compliant payment gateway that accepts most major credit and debit card brands from across the globe.
Get Appleton Conduit Body Fill Chart
Get form
Form Packages
Adoption
Bankruptcy
Contractors
Divorce
Home Sales
Employment
Identity Theft
Incorporation
Landlord Tenant
Living Trust
Name Change
Personal Planning
Small Business
Wills & Estates
Packages A-Z
Form Categories
Affidavits
Bankruptcy
Bill of Sale
Corporate - LLC
Divorce
Employment
Identity Theft
Internet Technology
Landlord Tenant
Living Wills
Name Change
Power of Attorney
Real Estate
Small Estates
Wills
All Forms
Forms A-Z
Form Library
Customer Service
Terms of Service
Privacy Notice
Legal Hub
Content Takedown Policy
Bug Bounty Program
About Us
Blog
Affiliates
Contact Us
Delete My Account
Site Map
Industries
Forms in Spanish
Localized Forms
State-specific Forms
Forms Kit
Legal Guides
Real Estate Handbook
All Guides
Prepared for You
Notarize
Incorporation services
Our Customers
For Consumers
For Small Business
For Attorneys
Our Sites
US Legal Forms
USLegal
FormsPass
pdfFiller
signNow
airSlate WorkFlow
DocHub
Instapage
Social Media
Call us now toll free:
+1 833 426 79 33
As seen in:
  • USA Today logo picture
  • CBC News logo picture
  • LA Times logo picture
  • The Washington Post logo picture
  • AP logo picture
  • Forbes logo picture
© Copyright 1997-2025
airSlate Legal Forms, Inc.
3720 Flowood Dr, Flowood, Mississippi 39232
Form Packages
Adoption
Bankruptcy
Contractors
Divorce
Home Sales
Employment
Identity Theft
Incorporation
Landlord Tenant
Living Trust
Name Change
Personal Planning
Small Business
Wills & Estates
Packages A-Z
Form Categories
Affidavits
Bankruptcy
Bill of Sale
Corporate - LLC
Divorce
Employment
Identity Theft
Internet Technology
Landlord Tenant
Living Wills
Name Change
Power of Attorney
Real Estate
Small Estates
Wills
All Forms
Forms A-Z
Form Library
Customer Service
Terms of Service
Privacy Notice
Legal Hub
Content Takedown Policy
Bug Bounty Program
About Us
Blog
Affiliates
Contact Us
Delete My Account
Site Map
Industries
Forms in Spanish
Localized Forms
State-specific Forms
Forms Kit
Legal Guides
Real Estate Handbook
All Guides
Prepared for You
Notarize
Incorporation services
Our Customers
For Consumers
For Small Business
For Attorneys
Our Sites
US Legal Forms
USLegal
FormsPass
pdfFiller
signNow
airSlate WorkFlow
DocHub
Instapage
Social Media
Call us now toll free:
+1 833 426 79 33
As seen in:
  • USA Today logo picture
  • CBC News logo picture
  • LA Times logo picture
  • The Washington Post logo picture
  • AP logo picture
  • Forbes logo picture
© Copyright 1997-2025
airSlate Legal Forms, Inc.
3720 Flowood Dr, Flowood, Mississippi 39232