Get Combustion Air Calculation Sheet

COMBUSTION AIR CALCULATION SHEET BLOCK LOT QUALIFICATION CODE PERMIT # WORK SITE ADDRESS (Street) (City) (Zip) Owner in Fee Tel. ( ) (ALL BTU RATINGS LISTED BELOW MUST BE INPUT RATING) Furnace BTUS.

How it works

  1. Open form

    Open form follow the instructions

  2. Easily sign form

    Easily sign the form with your finger

  3. Share form

    Send filled & signed form or save

How to fill out the Combustion Air Calculation Sheet online

The combustion air calculation sheet is a vital document used to ensure that sufficient combustion air is available for appliances, enhancing safety and efficiency. This guide will provide you with clear, step-by-step instructions on how to complete this form online.

Follow the steps to accurately fill out the combustion air calculation sheet.

  1. Click the ‘Get Form’ button to obtain the form and open it in the editing interface.
  2. Begin filling in the fields marked with block, lot, qualification code, and permit number. Provide the work site address, ensuring all relevant details such as street, city, and zip code are included.
  3. Enter the owner in fee's name and telephone number in the designated areas to keep complete contact information.
  4. Input the BTU ratings for all appliances including the furnace, hot water heater, gas dryer, and any other appliances. Be sure to include all BTU ratings, as noted, to calculate the total BTUs accurately.
  5. Calculate and enter the total BTU figure, summing all appliance BTUs listed. Then, use the formula provided (total BTUs × 50 cubic feet/1000) to determine the cubic feet of combustion air needed and input that figure.
  6. For the spaces available for combustion air, measure the length, width, and height of up to four spaces. Multiply these dimensions to compute the cubic feet for each space, entering the results accordingly.
  7. Add the results from all available spaces to calculate total cubic feet available. Ensure this matches the total cubic feet needed from the earlier calculation.
  8. If the total cubic feet available is less than what is needed, indicate in the provided section how additional combustion air will be supplied.
  9. Once all fields are completed and checked for accuracy, save your changes. You can then download, print, or share the form as required.

Start filling out your combustion air calculation sheet online today for efficient documentation and compliance.

Get form

Experience a faster way to fill out and sign forms on the web. Access the most extensive library of templates available.
Get form

Related content

COMBUSTION AIR WORK SHEET - Eastampton
*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the out...
Learn more
[PDF] Correctly Modeling and Calculating...
We will start with the combustion calculation which is necessary to calculate ... And the...
Learn more
VENTING ADDENDUM
(make sure air inlet on termination piece is free of restriction). 2. ... Secure pipe...
Learn more

Related links form

A PDF Version Of The Catalogue Can Be Downloaded ... - Dedman Gray Method Of Accelerating Delivery Of Magazines To A ... - Google Books Tenancy Application Form - Express Lettings Nottingham System And Methods For Highly Distributed Wide ... - Google Books

Questions & Answers

Get answers to your most pressing questions about US Legal Forms API.

Contact support

The volume of the space must equal 50 ft3 per 1000 BTU/hr. in addition to the infiltration air requirements. If the volume of the space is sufficient and the infiltration air is acceptable, then the indoor air method for calculating combustion air can be utilized.

Furnace btu's + Water heater btu's + dryer btu's = Total btu's 80,000 + 35,000 + 27,000 = 142,000 btu's 142,000 BTU x 50 / 1,000 = 7,100 cubic feet required Room size of: 1000 SF x 6.5 feet high = 6,500 cubic feet ---insufficient combustion air.

In this example we'll say that the furnace has an input rating of 80,000 BTU/hr and the water heater has an input rating of 40,000 BTU/hr. So the combined input rating is 120 when measured in 1,000 BTU/hr. So the room needs to have a volume of 120 x 50, or at least 6,000 ft3.

The International Fuel Gas Code requires the following combustion air openings for a boiler room: Vertical opening. One-inch free area for each 4,000 Btu/hr. ... Horizontal duct opening. One-inch free area for each 2,000 Btu/hr. ... Mechanical fan. One CFM of air for each 2,400 Btu/hr. ... Indoor air. 50 cu.

Where all combustion air and dilution air is provided by a mechanical forced-air system, the combustion air and dilution air shall be supplied at the minimum rate of 1 cfm per 2,400 Btu/h [0.00067 m3/(s • kW)] of combined input rating of all the fuel-burning appliances served.

To burn 1 cubic foot of gas, approximately 1,000 Btu for natural gas, requires 10 cubic feet of air for perfect combustion (Figure 2).

Combustion air from outside the dwelling 1) Direct opening to outside requires one square inch per 4000 BTU's (no duct). 2) Opening via horizontal duct requires one square inch per 2000 BTU's. 3) Opening via vertical duct requires one square inch per 4000 BTU's.

Get This Form Now!

Use professional pre-built templates to fill in and sign documents online faster. Get access to thousands of forms.
Get form
If you believe that this page should be taken down, please follow our DMCA take down processhere.

Industry-leading security and compliance

US Legal Forms protects your data by complying with industry-specific security standards.
  • In businnes since 1997
    25+ years providing professional legal documents.
  • Accredited business
    Guarantees that a business meets BBB accreditation standards in the US and Canada.
  • Secured by Braintree
    Validated Level 1 PCI DSS compliant payment gateway that accepts most major credit and debit card brands from across the globe.
Get Combustion Air Calculation Sheet
Get form
  • Adoption
  • Bankruptcy
  • Contractors
  • Divorce
  • Home Sales
  • Employment
  • Identity Theft
  • Incorporation
  • Landlord Tenant
  • Living Trust
  • Name Change
  • Personal Planning
  • Small Business
  • Wills & Estates
  • Packages A-Z
  • Affidavits
  • Bankruptcy
  • Bill of Sale
  • Corporate - LLC
  • Divorce
  • Employment
  • Identity Theft
  • Internet Technology
  • Landlord Tenant
  • Living Wills
  • Name Change
  • Power of Attorney
  • Real Estate
  • Small Estates
  • Wills
  • All Forms
  • Forms A-Z
  • Form Library
  • Legal Hub
  • About Us
  • Help Portal
  • Legal Resources
  • Blog
  • Affiliates
  • Contact Us
  • Delete My Account
  • Site Map
  • Industries
  • Forms in Spanish
  • Localized Forms
  • State-specific Forms
  • Forms Kit
  • Real Estate Handbook
  • All Guides
  • Notarize
  • Incorporation services
  • For Consumers
  • For Small Business
  • For Attorneys
  • USLegal
  • FormsPass
  • pdfFiller
  • signNow
  • altaFlow
  • DocHub
  • Instapage
Form Packages
  • Adoption
  • Bankruptcy
  • Contractors
  • Divorce
  • Home Sales
  • Employment
  • Identity Theft
  • Incorporation
  • Landlord Tenant
  • Living Trust
  • Name Change
  • Personal Planning
  • Small Business
  • Wills & Estates
  • Packages A-Z
Form Categories
  • Affidavits
  • Bankruptcy
  • Bill of Sale
  • Corporate - LLC
  • Divorce
  • Employment
  • Identity Theft
  • Internet Technology
  • Landlord Tenant
  • Living Wills
  • Name Change
  • Power of Attorney
  • Real Estate
  • Small Estates
  • Wills
  • All Forms
  • Forms A-Z
  • Form Library
Customer Service
  • Legal Hub
  • About Us
  • Help Portal
  • Legal Resources
  • Blog
  • Affiliates
  • Contact Us
  • Delete My Account
  • Site Map
  • Industries
  • Forms in Spanish
  • Localized Forms
  • State-specific Forms
  • Forms Kit
Legal Guides
  • Real Estate Handbook
  • All Guides
Prepared for you
  • Notarize
  • Incorporation services
Our Customers
  • For Consumers
  • For Small Business
  • For Attorneys
Our Sites
  • USLegal
  • FormsPass
  • pdfFiller
  • signNow
  • altaFlow
  • DocHub
  • Instapage
Social Media
Call us now toll free:
+1 833 426 79 33
As seen in:
© Copyright 1999-2026 airSlate Legal Forms, Inc. 3720 Flowood Dr, Flowood, Mississippi 39232
  • Your Privacy Choices
  • Terms of Service
  • Privacy Notice
  • Content Takedown Policy
  • Bug Bounty Program